JEQ Journal of Natural Resources and Life Sciences Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published in J Environ Qual 28:1757-1760 (1999)
© 1999 American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America
677 S. Segoe Rd., Madison, WI 53711 USA
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Williams, C. F.
Right arrow Articles by Nelson, S. D.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Williams, C. F.
Right arrow Articles by Nelson, S. D.
Agricola
Right arrow Articles by Williams, C. F.
Right arrow Articles by Nelson, S. D.

Design and Characterization of a New Dialysis Chamber for Investigating Dissolved Organic Matter-Organic Complexes

C. F. Williams*, W. J. Farmer, J. Letey and S. D. Nelson

Dep. of Environmental Science, Univ. of California, Riverside, CA 92521-0424.

* Corresponding author (williamc{at}mail.ucr.edu).

ABSTRACT

Equilibrium dialysis is commonly used to measure the complex formed between dissolved organic matter (DOM) and pesticides such as napropamide [2({alpha}-naphthoxy)-N,N-diethyl propionamide]. Currently the dialysis method most often used employs dialysis tubing that is clamped on both ends. Limitations of the dialysis tubing method include difficulty in sample addition to the dialysis tubing, dilution effects, and the need for large sample volumes. A new dialysis chamber constructed of Teflon and using flat dialysis membranes is described and characterized using napropamide as a model compound. Using a dialysis membrane with a molecular weight cut off of 500 Daltons the system reached equilibrium across the membrane within 120 h. Significant sorption of napropamide to the membrane was observed. Napropamide sorption was linear, reversible, and dependant on the membrane used. Sample addition and removal from the chamber is possible without destroying the integrity of the membrane. The dialysis chamber allowed for fast and easy quantitative addition and removal of sample for dialysis without wasting sample. The small chamber made possible dialysis of very small samples (as little as 1.5 ml.) while maintaining a large surface area for diffusion. The chamber also provided dialysis with a maximum dilution factor of two since the volume of dialysate needed is equal to the volume of sample introduced.


Received for publication September 30, 1999.


This article has been cited by other articles:


Home page
J. Environ. Qual.Home page
C. F. Williams, J. Letey, and W. J. Farmer
Molecular Weight of Dissolved Organic Matter-Napropamide Complex Transported through Soil Columns
J. Environ. Qual., March 1, 2002; 31(2): 619 - 627.
[Abstract] [Full Text] [PDF]


Home page
J. Environ. Qual.Home page
X. Huang and L. S. Lee
Effects of Dissolved Organic Matter from Animal Waste Effluent on Chlorpyrifos Sorption by Soils
J. Environ. Qual., July 1, 2001; 30(4): 1258 - 1265.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Agronomy Journal Crop Science
Journal of Natural Resources
and Life Sciences Education
Vadose Zone Journal
Soil Science Society of America Journal Journal of Plant Registrations The Plant Genome
Copyright © 1999 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America.