JEQ Journal of Natural Resources and Life Sciences Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published in J Environ Qual 25:601-610 (1996)
© 1996 American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America
677 S. Segoe Rd., Madison, WI 53711 USA
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fukui, Y.
Right arrow Articles by Doskey, P. V.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Fukui, Y.
Right arrow Articles by Doskey, P. V.
Agricola
Right arrow Articles by Fukui, Y.
Right arrow Articles by Doskey, P. V.

An Enclosure Technique for Measuring Nonmethane Organic Compound Emissions from Grasslands

Yoshiko Fukui and Paul V. Doskey*

Environmental Research Division, Argonne National Lab., 9700 South Cass Ave., Argonne, IL 60439.

* Corresponding author (paul__doskey{at}qmgate.anl.gov).

ABSTRACT

A static chamber technique for measuring emissions of nonmethane organic compounds (NMOCs) from soil surfaces and herbaceous vegetation in a natural setting has been developed. The technique involves the insertion of a polymethyl methacrylate frame into the ground. A polycarbonate chamber is placed in a water-containing trough on the frame to seal the chamber to the surface. The soil surface and vegetation are covered for various lengths of time, and samples of the chamber air are passively collected in preevacuated stainless steel canisters. The samples are analyzed in the laboratory by a whole-air cryogenic-preconcentration/high-resolution gas chromatographic technique with flame ionization detection. Changes in the concentrations of the NMOCs with time in the chamber are used to derive emission rates. The technique is sensitive and precise, but the occasional observation of nonlinear changes in NMOC concentrations in the chamber with the length of the covering period limits the accuracy of emission rates derived by this technique. Despite this limitation, the method is effective for identifying NMOC emissions and investigating seasonal variations of emission rates.


Received for publication April 17, 1995.


This article has been cited by other articles:


Home page
J. Environ. Qual.Home page
R. Reichman and D. E. Rolston
Design and Performance of a Dynamic Gas Flux Chamber
J. Environ. Qual., November 1, 2002; 31(6): 1774 - 1781.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Agronomy Journal Crop Science
Journal of Natural Resources
and Life Sciences Education
Vadose Zone Journal
Soil Science Society of America Journal Journal of Plant Registrations The Plant Genome
Copyright © 1996 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America.