JEQ Journal of Natural Resources and Life Sciences Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published in J Environ Qual 22:851-857 (1993)
© 1993 American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America
677 S. Segoe Rd., Madison, WI 53711 USA
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Blaylock, M. J.
Right arrow Articles by James, B. R.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Blaylock, M. J.
Right arrow Articles by James, B. R.
Agricola
Right arrow Articles by Blaylock, M. J.
Right arrow Articles by James, B. R.

Selenite and Selenate Quantification by Hydride Generation-Atomic Absorption Spectrometry, Ion Chromatography, and Colorimetry

Michael J. Blaylock*

Dep. of Plant, Soil, and Insect Sciences, P.O. Box 3354, Univ. of Wyoming, Laramie, WY 82071-3354;

Bruce R. James

Dep. of Agronomy, Univ. of Maryland, College Park, MD 20742.

* Corresponding author.

ABSTRACT

The need for a routine, inexpensive method with nanomolar detection limits for soluble SeO2–3 and SeO2–4 is increasing as Se research on soil-plant-water systems intensifies and speciation of Se valence states is required. This study was undertaken to compare hydride generation-atomic absorption spectrometry (HGAAS), colorimetry using 2,3-diaminonaphthalene (DAN), and ion chromatography (IC) as suitable methods for analysis of SeO2–3 and SeO2–4 in soil extracts and water samples. Selenium standards in solutions of either 1.0 mM KH2PO4, CaSO4, and KNO3, or in distilled water were analyzed to determine detection limits (DL), limits of quantitation (LOQ), and practicality for routine use of the above methods. A 0.1 mM K2HPO4/KH2PO4 soil extract spiked with 2.0 or 20 µM SeO2–3 and SeO2–4 was also used to compare the precision of the three methods. The HGAAS method was the most sensitive (0.212 absorbance units/µM) and had the lowest DL for SeO23 (0.03 µmol Se/L) of the three methods employed. Detection limits for the DAN and IC methods were significantly higher (18 and 0.24 µmol Se/L, respectively). Poor reproducibility between methods was obtained for SeO2–4 content of the soil extract containing 20 µM SeO2–4, with concentrations ranging from 9.1 ± 1.2 µmol/L determined by HGAAS to 24.6 ± 0.05 µmol/L by IC. The variability and poor recovery of SeO2–4 was due to variabilty in efficiency of the HCl reduction required to reduce SeO2–4 to SeO2–3 before analysis in the HGAAS and DAN procedures. Selenium determinations in samples where low detection limits (<0.1 µM) are required are most effectively accomplished with HGAAS. Colorimetry requires greater effort and time from the analyst to obtain the low detection limits of HGAAS, but is useful in that only a visible light spectrometer is required. Ion chromatography is capable of automated determinations of Se2–3 and SeO2–4 directly in combination with other ions of interest and may be appropriate for soil solution Se analysis where Se speciation is required.


NOTES

Contribution of the Maryland Agric. Exp. Stn. Sci. Art. no. A6380.

Received for publication June 12, 1992.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Agronomy Journal Crop Science
Vadose Zone Journal Journal of Plant Registrations
Journal of Natural Resources
and Life Sciences Education
Soil Science Society of America Journal
Copyright © 1993 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America.