Fig. 4. Water and pentafluorobenzoic acid (PFBA) breakthrough curves. The red line represents water flux while the black line denotes PFBA mass flux as a function of time after application. The PFBA mobile tracer was subjected to a 0.89 mm h1 irrigation rate. The green line represents the best fit line using the one-dimensional convectivedispersive equation (CDE).