Fig. 7. Experimental and simulated BTCs of SO4 effluent concentrations from the Bs horizon [column Bs-I, input SO4 (Co) of 0.005 M]. Simulations are based on best-fit of the data when a kinetic model (dashed curve) and kinetic model with an irreversible reaction (solid curve) were used.